Specifikationer
-
Installation
Clearance: 5 cm on sides and back.
Please see and follow detailed installation instructions provided with the unit
-
Refrigeration Data
Built-in Compressor and Refrigeration Unit
Refrigeration power at evaporation temperature: -10 °C
Operating temperature min.: 16 °C
Operating temperature max.: 40 °C
Condenser cooling type: AIR
-
Product Information (EN17032 – Commission Regulation EU 2015/1095)
Test performed in a test room at 30°C to chill/ freeze (+10°C/-18°C) a full load of 40mm deep trays filled with mashed potatoes evenly distributed up to a height of 35 mm at starting temperature between 65° and 80°C within 120/270min.
Chilling Cycle Time (+65°C to +10°C): 74 min
Full load capacity (chilling): 50 kg
Freezing Cycle Time (+65°C to -18°C): 255 min
Full load capacity (freezing): 50 kg
-
Electric
Circuit breaker required
Supply voltage: 380-415 V/3N ph/50 Hz
Heating power: 1.8 kW
-
Capacity
Max load capacity: 50 kg
Number and type of grids: 10 (GN 1/1; 600x400)
Number and type of basins: 14 (360x250x80h)
-
Key Information
Door hinges: Left Side
External dimensions, Width: 895 mm
External dimensions, Depth: 939 mm
External dimensions, Height: 1731 mm
Net weight: 233 kg
Shipping weight: 254 kg
Shipping volume: 1.98 m³
Number of positions & pitch: 29; 28.5 mm
-
Sustainability
Refrigerant type: R290
GWP Index: 3
Refrigeration power: 7255 W
Refrigerant weight (unit 1, unit 2): 150g; 150g
Energy consumption, cycle (chilling): 0.0836 kWh/kg
Energy consumption, cycle (freezing): 0.2508 kWh/kg
-
Water
Drain line size: 1"1/2
Dokumenter
Produktegenskaber
Included Accessories
Detergents and Chemicals (not included)